Technical parameter
Description | MH-4 | A-10 | S-20 |
| | | |
Measurement range | 0MPa~4MPa…100MPa | 0MPa~0.005MPa…100Mpa | 0MPa~0.04MPa…160MPa |
Overload pressure | 3×FS(max) | 2×FS(max) | 3×FS(max) |
Supply voltage | DC 8 ... 36 V | DC 8 ... 36 V | DC 8 ... 36 V |
Pressure medium | Liquid or gas | ||
Signal output type | 4~20mA、0.5~4.5V | ||
Nonlinear error | ≤±0.25%FS(max) | ≤±0.3%FS(max) | ≤±0.25%FS(max) |
Repeatability error | ≤±0.1%FS(max) | ≤±0.1%FS(max) | ≤±0.1%FS(max) |
Lag error | ≤±0.3%FS(max) | ≤±0.1%FS(max) | ≤±0.1%FS(max) |
Comprehensive accuracy | ≤±1%FS(max) | ≤±0.5%FS(max) | ≤±0.25%FS(typ.) |
Working temperature | -40 ...+125℃ | 0 ... +80 °C(standard) -40 ...+100℃(optional) | -30 ... +100 °C(standard) -40 ... +125 °C(optional) |
Medium temperature | -40 ...+125℃ | 0 ... +80 °C(standard) -40 ...+100℃(optional) | -30 ... +100 °C(standard) -40 ... +125 °C(optional) |
Vibration | 10~2000Hz,40g(IEC 68-2-64) | 10~500Hz,20g(IEC 68-2-64) | 10~2000Hz,20g(IEC 68-2-64) |
Shock | 100g,11ms(IEC 68-2-27) | 500g,6ms(IEC 68-2-27) | 100g,6ms(IEC 68-2-27) |
Protection grade | IP67(IEC 68-5-29) | IP67(IEC 68-5-29) | IP67(IEC 68-5-29) |
Life cycle | ≥100 million cycles | ≥100 million cycles | ≥100 million cycles |
Description | MH-CAN | MHS |
| ||
Measurement range | 0MPa~4MPa…60MPa | 0MPa~6MPa…60MPa |
Overload pressure | 3×FS(max) | 2×FS(max) |
Supply voltage | DC 8 ... 36 V | DC 6.5 ... 32 V |
Pressure medium | Liquid or gas | |
Signal output type | CANopen | Redundancy:4~20mA/20~4mA |
Nonlinear error | ≤±0.25%FS(max) | ≤±0.5%FS(max) |
Repeatability error | ≤±0.1%FS(max) | ≤±0.1%FS(max) |
Lag error | ≤±0.3%FS(max) | ≤±0.1%FS(max) |
Comprehensive accuracy | ≤±1%FS(max) | ≤±1.0%FS(max) |
Working temperature | -40 ...+125℃ | -40 ...+85℃ |
Medium temperature | -40 ...+125℃ | -40 ...+85℃ |
Vibration | 10~2000Hz,40g(IEC 68-2-64) | 10~2000Hz,10g(IEC 68-2-64) |
Shock | 100g,11ms(IEC 68-2-27) | 50g,11ms(IEC 68-2-27) |
Protection grade | IP67(IEC 68-5-29) | IP69K(IEC 68-5-29) |
Life cycle | ≥100 million cycles | ≥10 million cycles |
Certification | CE,UL Safety, EAC | CE,UL Safety, EAC,Conform to PLd CAT 3 standard |